Resources

Reference data for tube rolling work and the information we need to recommend tools.

What to send us for a quote

  • Tube OD and wall thickness (inch, mm or BWG)
  • Tube material
  • Tubesheet thickness and rolled length
  • Joint type: parallel, tapered or flared
  • Number of tubes and your schedule
  • Power available on site (voltage, phase) or compressed air
Request a Quote

Unit conversions

  • 1 in = 25.4 mm
  • 1 ft·lbf = 1.3558 N·m
  • 1 N·m = 0.7376 ft·lbf
  • 1 in·lbf = 0.1130 N·m
  • 1 lb = 0.4536 kg
  • 1 psi = 0.06895 bar

Tube wall gauge chart (BWG)

BWGWall (in)Wall (mm)
8.1654.19
9.1483.76
10.1343.40
11.1203.05
12.1092.77
13.0952.41
14.0832.11
15.0721.83
16.0651.65
17.0581.47
18.0491.24
19.0421.07
20.0350.89
21.0320.81
22.0280.71
23.0250.64
24.0220.56

Guides

How to Choose a Tube Expander: the Tube Data We NeedThe right tube expander depends on more than the tube OD. To match the expander to the job, we need the tube wall and material, tubesheet thickness, rolled length, joint type, and the square drive size of your tube roller.Read the guideHow to Set Tube Rolling Torque for Different Tube Materials and SizesThere is no single correct rolling torque. Set it by trial rolling the actual tube and tubesheet material, measure the wall reduction you get, and lock the torque that meets the design.Read the guideRolled Tube Joints Leaking After Hydrotest: Causes and FixesMost rolled joints that leak on hydrotest were under-rolled, over-rolled, or rolled into a dirty or oversized tube hole. Find the leaking joints one by one, re-roll at the correct rolling torque, and replace any tube that still leaks or has a cracked end.Read the guideHow Do I Produce Traceable Tube Rolling Records for Inspectors and Owners?Use tube rollers that record each joint and export the data, calibrate them regularly with a dynamic torque tester, and file the records by tubesheet and joint number. This replaces slow, error-prone handwritten logs with records you can hand over with the final documentation.Read the guideHow to Check and Calibrate Tube Roller TorqueRun the tube roller on a dynamic torque tester, read the actual output torque in real time and compare it with the setting. Adjust or repair any tool outside tolerance, then calibrate on a regular schedule and keep records.Read the guideRolling Titanium Condenser Tubes: What to Watch ForTitanium condenser tubes are easy to over-roll because the walls are thin, and easy to under-roll because titanium springs back more than copper. Clean tube holes, set rolling torque from trial rolling, and roll every joint at the same controlled torque with a five-roll tube expander.Read the guideHow Do You Roll Thick-Wall and Large-Diameter Steel Tubes?Thick-wall and large-diameter steel tubes need more rolling torque than a standard tube roller delivers, and more reaction torque than an operator can hold by hand. The fix is to match the drive to the tube size and wall: a large-tube electric roller or a hydraulic roller, with a reaction arm or balancing arm taking the load.Read the guideTube Rolling in Hazardous Areas: How to Choose an Explosion-Proof Tube RollerDo not use an electric or servo tube roller in a hazardous area. Use an air-driven or hydraulic tube roller instead, and make sure the drive or power unit is certified for the area classification on site.Read the guideHow Do You Retube a Condenser on a Tight Outage Schedule?Most condenser retubes overrun because tools are late or too few and crews hand work back and forth. Fix it before the outage: calculate the daily output each step needs, size the tool set to match, prove out rolling and welding in advance, and run pulling through welding with one crew.Read the guideHow to Remove Tubes from a Condenser or Heat Exchanger FasterTube removal usually runs slow for three reasons: the puller doesn't have enough force, each spear has to be threaded into the tube, or tubes break off in the tubesheet. Cut the tubes at the support plate first, then match the puller and spear type to the tube and the space you're working in.Read the guideHow to Find Leaking Tubes in a CondenserTake the condenser off line and vacuum-test every tube with a vacuum tube leak detector (VTLD). An unstable gauge reading marks a leaking tube. Then check the tube-to-tubesheet joints with a vacuum joint leak detector (VJLD) to separate tube leaks from joint leaks.Read the guideLeaking Heat Exchanger Tubes: Plug or Retube?Plug a few leaking tubes to get the unit back on line fast. Retube or replace the bundle when plugged tubes approach the design margin or plant limit, performance drops, or the tubes show general wall loss.Read the guide