Photos may show optional equipment.
Vacuum Joint Leak Detector (VJLD)
Finds leaking tube-to-tubesheet joints one by one, using vacuum and shop compressed air.
The VJLD seals the tube bore and the tubesheet face around one joint and pulls a vacuum on it. If the vacuum is lost, that joint leaks and can be repaired right away. It works on expanded or welded joints and runs on standard compressed air, with no electrics.
Key features
- Tests expanded or welded tube-to-tubesheet joints
- Covers tube OD 3/8 in to 2-1/2 in (9.5 to 63.5 mm)
- Interchangeable manifolds and seal sets for different tube sizes
- Under 2.7 lb (1.2 kg) with a 3/4 in manifold
- Runs on shop air at 40 to 125 psi (2.8 to 8.6 bar)
At a glance
- Tube OD range
- 3/8 in to 2-1/2 in (9.5 to 63.5 mm)
- Air supply pressure
- 40 to 125 psi (2.8 to 8.6 bar)
- Weight
- Less than 2.7 lb (1.2 kg) with 3/4 in manifold
- Joint types
- Expanded or welded
- Tube materials
- Any
- Country of origin
- China
Specifications
| Specification | Value |
|---|---|
| Tube OD | 3/8 in to 2-1/2 in (9.5 mm to 63.5 mm) |
| Tube materials | Any |
| Joint types | Expanded or welded tube-to-tubesheet joints |
| Compressed air pressure | 40 to 125 psi (2.8 to 8.6 bar) |
| Weight | Less than 2.7 lb (1.2 kg) with 3/4 in manifold |
| Size change | Interchangeable manifolds and seal sets |
How it works
The tester seals the inside of the tube and the tubesheet face around the joint. Compressed air drives the vacuum generation, so the tool needs no electrical supply.
A vacuum is drawn on the joint. If the vacuum holds, the joint is tight. If it drops, the joint leaks and is marked for repair before the next joint is tested.
Applications
- Heat exchanger manufacturing
- Retubing projects
- Maintenance and repair of tube-to-tubesheet joints in various equipment
Information needed to order
Manifolds and seal sets are matched to the job. Please provide:
- Tube outer diameter and wall thickness
- Number of tubes (joints) to be tested
- Tube pitch, spacing and layout (if known)
- Length or depth of any channel head present
Frequently asked questions
Can the VJLD test welded joints as well as rolled joints?
Yes. It is used on tube-to-tubesheet joints that are expanded or welded.
How do I change the VJLD to another tube size?
Fit the manifold and seal set for that tube OD. Interchangeable sets cover 3/8 in to 2-1/2 in (9.5 to 63.5 mm) tube OD.
What utilities does the VJLD need?
Only standard compressed air at 40 to 125 psi (2.8 to 8.6 bar). It has no electrical components.
Why do you ask for the channel head depth when ordering?
The tool has to reach the tubesheet face through the channel head, so its depth affects how the tester is configured for access.