Testing & Inspection

Vacuum Joint Leak Detector (VJLD)

Finds leaking tube-to-tubesheet joints one by one, using vacuum and shop compressed air.

The VJLD seals the tube bore and the tubesheet face around one joint and pulls a vacuum on it. If the vacuum is lost, that joint leaks and can be repaired right away. It works on expanded or welded joints and runs on standard compressed air, with no electrics.

Key features

  • Tests expanded or welded tube-to-tubesheet joints
  • Covers tube OD 3/8 in to 2-1/2 in (9.5 to 63.5 mm)
  • Interchangeable manifolds and seal sets for different tube sizes
  • Under 2.7 lb (1.2 kg) with a 3/4 in manifold
  • Runs on shop air at 40 to 125 psi (2.8 to 8.6 bar)
Request a quote for this product

At a glance

Tube OD range
3/8 in to 2-1/2 in (9.5 to 63.5 mm)
Air supply pressure
40 to 125 psi (2.8 to 8.6 bar)
Weight
Less than 2.7 lb (1.2 kg) with 3/4 in manifold
Joint types
Expanded or welded
Tube materials
Any
Country of origin
China

Specifications

SpecificationValue
Tube OD3/8 in to 2-1/2 in (9.5 mm to 63.5 mm)
Tube materialsAny
Joint typesExpanded or welded tube-to-tubesheet joints
Compressed air pressure40 to 125 psi (2.8 to 8.6 bar)
WeightLess than 2.7 lb (1.2 kg) with 3/4 in manifold
Size changeInterchangeable manifolds and seal sets

How it works

The tester seals the inside of the tube and the tubesheet face around the joint. Compressed air drives the vacuum generation, so the tool needs no electrical supply.

A vacuum is drawn on the joint. If the vacuum holds, the joint is tight. If it drops, the joint leaks and is marked for repair before the next joint is tested.

Applications

  • Heat exchanger manufacturing
  • Retubing projects
  • Maintenance and repair of tube-to-tubesheet joints in various equipment

Information needed to order

Manifolds and seal sets are matched to the job. Please provide:

  • Tube outer diameter and wall thickness
  • Number of tubes (joints) to be tested
  • Tube pitch, spacing and layout (if known)
  • Length or depth of any channel head present

Frequently asked questions

Can the VJLD test welded joints as well as rolled joints?

Yes. It is used on tube-to-tubesheet joints that are expanded or welded.

How do I change the VJLD to another tube size?

Fit the manifold and seal set for that tube OD. Interchangeable sets cover 3/8 in to 2-1/2 in (9.5 to 63.5 mm) tube OD.

What utilities does the VJLD need?

Only standard compressed air at 40 to 125 psi (2.8 to 8.6 bar). It has no electrical components.

Why do you ask for the channel head depth when ordering?

The tool has to reach the tubesheet face through the channel head, so its depth affects how the tester is configured for access.

Related guides

Request a quote for this product

Tell us your tube size, material and quantity. We reply with the right configuration.

Request a Quote